Testing Services
IsoVac Engineering provides RadifloŽ leak testing service at our
Glendale, CA facility using
all of the latest RadifloŽ equipment and covering all of the Mil Standards as
well as those company specifications which have been written specifically around
the RadifloŽ leak detection process. The IsoVac testing laboratories have routinely
tested 40 to 60,000 devices per day for single customers. This service
is both in conjunction with the manufacture and the delivery of RadifloŽ
equipment, as well as allowing the RadifloŽ user a back up facility
for those months where excessively high production has been encountered. In addition to
the routine Mil Standard leak testing, IsoVac Engineering provides many companies
with special test methods which have been written specifically for their
devices. New designs as well as packaging characteristics which are
challenging, and in most cases impossible to leak test, are welcome at IsoVac Engineering.
An engineering evaluation
test will always be performed to determine if
the package is testable by the RadifloŽ process.
IsoVac complies with the following military specifications.
- MIL-Std-202
- MIL-Std-19500
- MIL-Std-38103 B
- Missile SPEC 135
|
- MIL-Std-883 (Method 1014)
- MIL-Std-750 (Method 1071)
- MIL-R-6106
|
IsoVac also provides extensive failure analysis of devices that fail leak
testing, micro sectioning, photomicrographs, complete analytical engineering
reports and expert witness support.
|